Advantages at a glance

  • Made of robust V2A steel
  • Design on request (0.1 to 20 liters)
  • Good alternative to gauging tests
  • Inexpensive and durable

Please send me more information about UGT Tipping counter V2A

UGT Tipping counter V2A

Tipping counters are used for the quantitative determination of seepage water and surface water runoff. For this purpose, the direct quantity of water flowing off is recorded as a flow rate (also volume flow). The flow rate indicates which volume of a fluid flows through a certain cross-sectional area in a certain time. Tipping counters thus offer a highly time-resolved, automated alternative to leaching tests.

The tipping counters made of V2A steel are very robust and inert to water of different origin and composition. Due to the stable material, significantly larger designs are possible than with plastic tipping meters. To accommodate all flow volumes, these tipping counters are available with a wide range of tipping pan sizes - from 0.1 to 20 liters. From a volume of 5 liters, we recommend an open design.

Note: The operating temperature for our V2A tipping meters is up to 0 °C. Below freezing point, freezing of the water must be expected, especially in the inlet. To prevent the water from freezing, the entire tipping meter can be encased, insulated and/or fitted with pipe trace heating on request. Please specify this when ordering.

Fields of application:

  • Detection of leachate rates in lysimeters.
  • In combination with the Run Off system, tipping counters can be used to measure surface runoff on slopes. Surface runoff plays a significant role in the hillslope hydrology of small catchments.
  • When combined with the H-Flume, tipping counters provide high measurement accuracy during low-flow conditions, while the H-Flume accurately measures higher flows in open channels.

Up to a tipping bucket volume of three liters, the tipping counters are equipped with a connection for aliquot sampling. For each tipping, 0.1...3 % volume aliquote is then filled into a PE collection bottle for further analysis in the laboratory via an outlet connection with hose connection and shut-off valve.

  • V2A tipping counter 0.1 l counting volume (article no.: 1920000)
  • V2A tipping counter 0.1 l counting volume, with adequate sampling* (article no.: 1912000)
  • V2A tipping counter 0.25 l counting volume (article no.: 1920500)
  • V2A tipping counter 0.25 l counting volume, with adequate sampling* (article no.: 1920550)
  • V2A tipping counter 0.5 l counting volume (article no.: 1921000)
  • V2A tipping counter 0.5 l counting volume, with adequate sampling* (article no.: 1921100)
  • V2A tipping counter 1.0 l counting volume (article no.: 1922000)
  • V2A tipping counter 1.0 l counting volume, with adequate sampling* (article no.: 1922100)
  • V2A tipping counter 2.0 l counting volume (article no.: 1923000)
  • V2A tipping counter 2.0 l counting volume, with adequate sampling* (article no.: 1923100)
  • V2A tipping counter 3.0 l counting volume (article no.: 1924000)
  • V2A tipping counter 3.0 l counting volume, with adequate sampling* (article no.: 1924100)
  • V2A tipping counter 5.0 l counting volume, open design (article no.: 1925000)
  • V2A tipping counter 5.0 l counting volume, closed design (article no.: 1925010)
  • V2A tipping counter 10.0 l counting volume, open design (article no.: 1926000)
  • V2A tipping counter 20.0 l counting volume, open design (article no.: 1925100)

* Tipping counters with adequate sampling are supplied with PE collection bottle and bottle magazine.

L

0,1 l

0,25 l

0,5

1

2

3

5

10

20

Max. flow rate in l/min

 

2

4

7

12

24

 

36

60

120

240

Dimensions

W x D x H in cm

33 x

19 x

21.5

29 x

23 x

34

29 x

23 x

34

28 x

42 x

35

37 x

41 x

37

44 x

46 x

43

61 x

29 x

37

70 x

36 x

43

88 x

45 x

55

Weight in kg

3.2

5.7

6.6

9.4

13.2

17

11

18

32

Design

closed

open

Material

stainless V2A steel

Features

Robust and chemically inert toward water of various sources and compositions,

Operating temperature down to 0 °C; insulation and/or pipe tracing available

Tipping bucket

Vol. per tray in ml

100

250

500

1.000

2.000

3.000

5,000

10,000

20,000

Bearing

adjustable double-sided knife-edge bearing

Flange bearing

adjustable double-point bearing

Hose connection

Inlet/outlet connections in mm

Ø 20

Ø 34

Ø 34

Ø 34

Ø 34 / 50

Ø 50

free outlet for installation in a manhole

Inlet height in mm

197

315

315

320

340

390

 

 

 

Drain height in mm

42

65

65

70

70

50

 

 

 

Base

Features

Holes for horizontal mounting; wall mounting available upon request

Holes for horizontal mounting

Pulse transmitter

Features

Reed switch with permanent magnet on the tipping bucket,

including terminal block for connection cables

Max. switching current

0.5 A

Max. switching voltage

200 V

Clamping range

up to 1.5 mm²

Aliquot sampling

Flow rate

0.1 ... 3 % of the total flowed through / tipped water volume